| CONTRAST VIS | CONTRAST SWIR | CONTRAST X |
SPECTRAL RANGE (extended and reduced spectral ranges also available**) | 400 - 1000 nm | 1000 - 2300 nm (2500 nm optional*) | where X represents a custom spectral range |
BANDWIDTH (FWHM)*** | 1.0 nm - 2.5 nm | 2.0 nm - 5 nm | High resolution: 0.15 nm - 0.9 nm |
OUT OF BAND REJECTION**** | < -60="" db="" @="" ±="" 40=""> | < -60="" db="" @="" ±="" 80=""> (measured up to 1.7 µm) | depends on the bandwidth |
MAXIMUM INPUT AVERAGE POWER HP4: UP TO 4W HP8: UP TO 8W HP20: UP TO 20W | HP8, HP20 | HP8, HP20 | HP4 |
PEAK EFFICIENCY | typically around 65% |
OPTICAL DENSITY (OD) | > OD6 (measured at 1064 nm) | TBD |
SPECTRAL POWER DENSITY | Coupled with 4W supercontinuum source: < 1="" -="" 3=""> Coupled with 8W supercontinuum source: < 2="" -="" 5=""> | Coupled with 4W supercontinuum source: < 2="" -="" 5=""> Coupled with 8W supercontinuum source: < 5="" -="" 9=""> | depends on the bandwidth |
DAMAGE THRESHOLD | < 5="">2 peak power @ 1064 nm, 8 ns |
BEAM DIAMETER | 2 to 5 mm (depending on λ) |
INPUT BEAM DIVERGENCE REQUIREMENT | < 0.45=""> |
WAVELENGTH RELATIVE ACCURACY | FWHM / 8 |
POINTING STABILITY | < 1mm="" lateral="">lacement @ 1 m from |
SCANNING SPEED (MULTIPLE STEP) | 35 ms stabilization time for 0.1 nm step, 45 ms stabilization time for 0.2 nm step, 55 ms stabilization time for 1 nm step, 60 ms stabilization time for 2 nm step, 65 ms stabilization time for 5 nm step, 70 ms stabilization time for 10 nm step, |
OPERATING SYSTEM (OS) | Windows Vista (32 & 64 bits) Windows 7 (32 & 64 bits) Windows 8 (32 & 64 bits) |
SOFTWARE | included (SDK available) |
COMPUTER CONNECTION | USB 2.0 (compatible 1.1) |
DIMENSIONS (L x W x H) | 9'' x 6.3'' x 6.7'' (filter) 23 cm x 16 cm x 17 cm (filter) |
OPERATING TEMPERATURE | 5 to 40°C |
STORAGE TEMPERATURE | 0 to 50°C |
POWER SUPPLY | 100 - 240 V, 50 - 60 Hz |
|
ENHANCED SWIR | N/A | * up to 2500 nm |
FIBEROPTIC OUTPUT | An X-Y-Z translation adjustment allows coupling optimization. The FC APC is available with the following fibers: - 9/125 μm (single mode) - 50/125 μm (multimode) - 105/125 μm (multimode) |
HARMONIC FILTER | Blocks the harmonics coming from the region 400-500 nm | Blocks the harmonics coming from the region 500-1000 nm and/or 1000-1250 nm | A filtre is chosen according to the spectral range |
ALIGNMENT KIT (FOR FREE SPACE) | In free-space (input/output) configuration, the alignment kit allows the user to rapidly find the correct alignment |
** EXTENDED AND REDUCED SPECTRAL RANGES ALSO AVAILABLE | e.g.: 500-2000 nm, 400-1700 nm, 500-900 nm, 500-650 nm, 650-1000 nm, 1000-1700 nm, 1700-2300 nm, etc. |